SPECIAL FUNCTIONS
18 D-302755
6. Special Functions
Looking after People Left at Home
An important characteristic of the
PowerMaxComplete is its ability to function in a
mode contrary to the usual behavior of an alarm
system. When the system is in the disarmed state (or
even when armed “HOME” with perimeter protection
only), it can keep track of in-house activity and will
report lack of motion in interior zones if there is no
detection of motion within predetermined time limits.
To use this characteristic, you must ask your installer
to program a specific time limit beyond which lack of
motion will be reported as a “not active” alert.
To make things clear, let us assume that an elderly,
sick or handicapped person is left unattended in a
protected site. This person, disabled or sick as he
may be, will not stay entirely still for hours. It is only
natural that even while being asleep he will turn over
in his bed from time to time. He might also wander
into the kitchen to eat or drink, or to the bathroom for
other necessities. Upon doing so, the bedroom,
bathroom and kitchen motion detectors will detect his
movement.
If, for example, the “lack of motion” time limit is set by
your installer to 6 hours, a virtual 6-hour clock will
carry out a 6-hour “countdown”.
If motion is detected
within the 6-hour time frame, the
countdown will restart from the beginning (the virtual
6-hour clock will be “reset”) and no alert message will
be sent out.
If no motion is detected
within the 6-hour time frame
in any interior zone, the control panel will send a
not-active” alert message to the central monitoring
station or to private telephones designated by the
installer.
IMPORTANT! In addition, you may provide the
person confined to interiors with a single-button
transmitter for distress situations, see next
paragraph.
Emergency Calls for Help
Suppose the disabled person discussed above has
an accident such as falling in the bathtub without
being able to get up. It might take hours before the
“No Active” alert is sent out, but he (or she) must be
assisted much sooner.
Even though the odds for such an accident are not
high, it is advisable to provide the disabled person with
a miniature, single-button pendant-type or wristwatch-
type transmitter. Pressing the button on this
transmitter will cause the PowerMaxComplete to send
an “emergency call” to the central monitoring station
or to private telephones designated by the installer.
To make this possible, ask your installer to define
one of the 28 zones of the PowerMaxComplete as an
emergency zone.
Then, obtain one of the transmitters listed below and
link this transmitter’s ID code to the emergency zone.
Compatible distress transmitters are (see Fig. 5):
MCT-201 - pendant-type
MCT-211 - wristwatch-type
MCT-101 - pocket-type
MCT-201
MCT-211
MCT-101
Figure 5. Single-button Emergency Transmitters
Remote Control by Telephone
control
panel
A. Establishing Telephone Communication
You can access the PowerMaxComplete system
from a remote telephone and perform arming and
disarming, activation and deactivation of electrical
devices and the auxiliary output (PGM), record,
playback and erase a voice message, and
investigate the system status. The process is shown
in the next illustration.
1. Dial the PowerMaxComplete tel. No.
2. Wait for 2-4 rings then hang
up.
3. Wait 12-30 sec.
4. Redial
PowerMaxComplete tel.
No. (Sound will be heard
for 10 sec.).
Not applicable
when dialing to the
GSM number of
the
PowerMaxComple
te. Proceed to
step 5.
5. [*} (to stop the sound)
1
6. [user code], [#]
2
7.
[Desired command, see next table]
3
Notes
(1) The PowerMaxComplete responds in a similar
way if you just dial once and wait until you hear
telephone rings (in USA, for example, 11 rings).
(2) Entering of user code is required once only.
(3) If you wait more that 50 seconds (may change
according to setup / use) without keying a
command, the PowerMaxComplete will disconnect
the line.