Visonic POWERMAX - User's Guide Page 20

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 19
20 DE5450P
APPENDIX A. EVENT CODES
APPENDIX A. EVENT CODESAPPENDIX A. EVENT CODES
APPENDIX A. EVENT CODES
Contact ID Event Codes
Code Definition
101
Emergency
110
Fire
120
Panic
122
Silent
123
Audible
131
Perimeter
132
Interior
134
Entry/Exit
137
Tamper/CP
301
AC loss
302
Low system battery
321
Bell
344
RF receiver jam detect
350
Communication trouble
351
Telco fault
381
Loss of supervision RF
383
Sensor tamper
384
RF low battery
401
O/C by user
406
Cancel
408
Quick arm
441
Armed home
456
Partial arm
459
Recent close
602
Periodic test report
607
Walk test mode
641
Senior watch trouble
SIA Event Codes
Code Definition
AR
AC Restore
AT
AC Trouble
BA
Burglary Alarm
BC
Burglary Cancel
BR
Burglary Restore
BT
Burglary Trouble / Jamming
BZ
Missing Supervision
CF
Forced Closing
CL
Closing Report
FA
Fire Alarm
FR
Fire Restore
LR
Phone Line Restore
LT
Phone Line Trouble
OP
Opening Report
PA
Panic Alarm
QA
Emergency Alarm
RP
Automatic Test
RX
Manual Test
RY
Exit from Manual Test
TA
Tamper Alarm
TR
Tamper Restore
XR
Sensor Battery Restore
XT
Sensor Battery Trouble
YR
System Battery Restore
YT
System Battery Trouble
YX
Service Required
4/2 Event Codes
Alarms
Zone No.
123456789101112131415
1
st
digit
444444444444444
2
nd
digit
123456789ABCDEF
Zone No.
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
1
st
digit 555555555555555
2
nd
digit 123456789ABCDEF
Restorals
Zone No.
123456789101112131415
1
st
digit CCCCCCCCCCCCCCC
2
nd
digit 123456789ABCDEF
Zone No.
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
1
st
digit DDDDDDDDDDDDDDD
2
nd
digit 123456789ABCDEF
Page view 19
1 2 ... 15 16 17 18 19 20 21 22 23 24

Comments to this Manuals

No comments